TABLAS
DE CONVERSIÓN
| Unidades
de mercadería (aprox.) por kg |
Medida
de producto |
1.50 |
2.00 |
2.50 |
3.00 |
4.00 |
5.00 |
33% |
50% |
fina |
Electrodos
13A |
|
94 |
54 |
33 |
21 |
|
|
|
|
Varilla
de bronce |
170 |
40 |
28 |
19 |
11 |
7 |
|
|
|
Varilla
de aluminio |
|
135 |
84 |
60 |
34 |
22 |
|
|
|
Estaño
en barra |
|
|
|
|
|
|
7 a 8 |
7 a 8 |
|
Plata
autodeter. |
|
|
|
|
|
|
|
|
54 |
Arriba
| Medida(Pulgadas) |
Largo (mm) |
Diametro
(mm) |
Cantidad (Kg) |
| 1 |
25 |
2.2 |
1353 |
| 1
1/4 |
38 |
2.4 |
687 |
| 2 |
50 |
2.7 |
404 |
| 2
1/4 |
63 |
3.4 |
216 |
| 3 |
76 |
4.1 |
119 |
| 4 |
102 |
4.5 |
85 |
Arriba
Medida |
Largo (mm) |
Cantidad (Kg) |
12
x 35 |
1.80 |
1822 |
12
x 32 |
1.80 |
1460 |
12
x 38 |
1.80 |
1247 |
13
x 32 |
2.00 |
1192 |
13
x 38 |
2.00 |
1017 |
14
x 38 |
2.20 |
823 |
14
x 45 |
2.20 |
705 |
15
x 50 |
2.40 |
534 |
16
x 63 |
2.70 |
338 |
17
x 75 |
3.00 |
232 |
Arriba
Medida
(Pulgadas) |
Largo (mm) |
Cantidad (Kg) |
1 |
25.4 |
1850 |
1
1/2 |
38.1 |
935 |
2 |
50.8 |
570 |
2
1/2 |
63.5 |
312 |
3 |
76.2 |
203 |
4 |
101.5 |
105 |
5 |
127 |
56 |
6 |
152.4 |
45 |
Arriba
Calibre
Nro. |
Diámetro
(mm) |
Metros por Kg |
4 |
5.89 |
5 |
5 |
5.38 |
6 |
6 |
4.87 |
7 |
7 |
4.47 |
8 |
8 |
4.06 |
10 |
9 |
3.65 |
12 |
10 |
3.25 |
15 |
11 |
2.94 |
19 |
12 |
2.64 |
23 |
13 |
2.33 |
30 |
14 |
2.03 |
40 |
14
1/2 |
1.90 |
45 |
15 |
1.82 |
50 |
16 |
1.62 |
60 |
17 |
1.42 |
80 |
18 |
1.22 |
110 |
Arriba
| Alambre
ovalado de mediana resistencia |
| Calibre
Nro. |
Diam. (mm) |
Carga de Rotura |
Peso |
Longitud |
|
N |
Kg |
Kg/rollo |
m/rollo |
| 16/14 |
2.70/2.20 |
3.381 |
345 |
36 |
1000 |
| 17/15 |
3.00/2.40 |
3.871 |
395 |
43 |
1000 |
| Alambre
ovalado de alta resistencia |
| Calibre
Nro. |
Diam. (mm) |
Carga de Rotura |
Peso |
Longitud |
|
N |
Kg |
Kg/rollo |
m/rollo |
| 17/15 |
3.00/2.40 |
7.100 |
725 |
43 |
1000 |
| Alambre
redondo de alta resistencia |
| Calibre
Nro. |
Diam. (mm) |
Carga de Rotura |
Peso |
Longitud |
|
N |
Kg |
Kg/rollo |
m/rollo |
| |
2.25 |
5.580 |
600 |
32 |
1000 |
| 12 |
2.64 |
7.350 |
750 |
43 |
1000 |
| 9 |
3.66 |
11.760 |
1.2 |
42 |
500 |
Arriba
| Alambre
galvanizado de alta resistencia |
| Tipo |
Nro. |
Diam.(mm) |
Dist.
entre puas |
Peso |
Long. |
| mm |
Pulg |
Kg/ Rollo |
m/
Rollo |
| 15-127 |
15 |
1.83 |
127 |
5 |
27.8 |
500 |
| 15-101 |
15 |
1.83 |
101.6 |
4 |
30 |
500 |
| 15-76 |
15 |
1.83 |
76.2 |
3 |
32 |
500 |
| 16-101 |
16 |
1.83 |
101.6 |
4 |
23.5 |
500 |
Arriba
| Calorías
de algunos combustibles por kg. |
| Designación |
Calorías |
| Aceite
de alquitrán de lignito |
10000 |
| Alcohol
etílico |
7100 |
| Alcohol
metílico |
5300 |
| Benceno
(benzol) |
10000 |
| Butano |
10900-11800 |
| Carbón
a leña |
6000-7000 |
| Celulosa |
4200 |
| Cera |
9000 |
| Cloruro
de metilo |
3200 |
| Diesel-oil |
10700 |
| Etano |
11300-12350 |
| Fuel-oil |
10300 |
| Gas
envasado nro. 1 |
11878 |
| Gas
envasado nro. 3 |
12013 |
| Gas-oil |
10900 |
| Hidrógeno |
34000 |
| Kerosene |
11100 |
| Metano |
11900-13250 |
| Nafta |
11200 |
| Petróleo |
10500-11200 |
| Propano |
11050-12000 |
Arriba
| Celcius
( C ) |
Reamur ( R ) |
Fahrenheit ( F ) |
| -20 |
-16.0 |
-4.0 |
| -15 |
-12.0 |
5.0 |
| -10 |
-8.0 |
14.0 |
| -5 |
-4.0 |
23.0 |
| -4 |
-3.2 |
24.8 |
| -3 |
-2.4 |
26.6 |
| -2 |
-1.6 |
28.4 |
| -1 |
-0.8 |
30.2 |
| 0 |
0.0 |
32.0 |
| 1 |
0.8 |
33.8 |
| 2 |
1.6 |
35.6 |
| 3 |
2.4 |
37.4 |
| 4 |
3.2 |
39.2 |
| 5 |
4.0 |
41.0 |
| 6 |
4.8 |
42.8 |
| 7 |
5.6 |
44.6 |
| 8 |
6.4 |
46.4 |
| 9 |
7.2 |
48.2 |
| 10 |
8.0 |
50.0 |
| 11 |
8.8 |
51.8 |
| 12 |
9.6 |
53.6 |
| 13 |
10.4 |
55.4 |
| 14 |
11.2 |
57.2 |
| 15 |
12.0 |
59.0 |
| 16 |
12.8 |
60.8 |
| 17 |
13.6 |
62.6 |
| 18 |
14.4 |
64.4 |
| 19 |
15.2 |
66.2 |
| 20 |
16.0 |
68.0 |
| 25 |
20.0 |
77.0 |
| 30 |
24.0 |
86.0 |
| 40 |
32.0 |
104.0 |
| 50 |
40.0 |
122.0 |
| 60 |
48.0 |
140.0 |
| 70 |
56.0 |
158.0 |
| 80 |
64.0 |
176.0 |
| 90 |
72.0 |
194.0 |
| 100 |
80.0 |
212.0 |
Arriba
| Sección
mínima admisible de conductores |
| Conductor
aislado |
Sección Min (mm2) |
| En
artefactos |
0.50 |
| Dentro
de caños, o sobre aisladores distanciados no más de 1
m |
1.00 |
| A
la intemperie, o sobre aisladores distanciados no más
de 1 m |
2.50 |
| A
la intemperie, o sobre aisladores distanciados no más
de 1 y 10 m |
4.00 |
| A
la intemperie, o sobre aisladores distanciados a más de
10 m |
6.00 |
| En
colgantes y cordones flexibles |
0.75 |
| En
líneas generales |
2.50 |
Arriba
| Intensidad
máxima admisible para conductores aislados |
| Sección
de cobre mm2 |
Intensidad A |
|
Sección de cobre
mm2 |
Intensidad
A |
| 1 |
6 |
95 |
195 |
| 1.5 |
9 |
120 |
235 |
| 2.5 |
15 |
|
270 |
| 4 |
22 |
185 |
320 |
| 6 |
30 |
240 |
380 |
| 10 |
40 |
310 |
460 |
| 16 |
55 |
400 |
550 |
| 25 |
75 |
500 |
650 |
| 35 |
95 |
625 |
750 |
| 50 |
120 |
800 |
900 |
| 70 |
155 |
1000 |
1050 |
Arriba
| Caños
de hierro galvanizado |
Diam.
Ext.
mm |
Diam. Interior |
Peso aprox. x mts |
| mm |
Pulg |
Kg |
| 13 |
6.40 |
1/4 |
0.66 |
| 17 |
9.50 |
3/8 |
0.86 |
| 21 |
12.70 |
1/2 |
1.29 |
| 27 |
19.05 |
3/4 |
1.67 |
| 34 |
25.40 |
1 |
2.51 |
| 42 |
31.75 |
1 1/4 |
3.2 |
| 48 |
38.10 |
1 1/2 |
3.96 |
| 60 |
50.80 |
2 |
5.31 |
| 75 |
63.50 |
2 1/2 |
6.87 |
| 89 |
76.20 |
3 |
8.65 |
| 114 |
101.60 |
4 |
11.91 |
| 140 |
127.00 |
5 |
15.6 |
| 165 |
152.40 |
6 |
18.83 |
Arriba
Si
Ud.
desea puede presionar aqui para bajar
un programa de Conversión de Medidas.
El mismo es un ejecutable y mide 578KBytes.
|
|
|